AR-LBD Reference Set 1 % AF cfDNA
The AR-LBD Reference Set is a quality control material designed for assays detecting mutations in the ligand-binding domain (LBD) of the androgen receptor (AR) gene at the cell-free DNA (cfDNA) level.
The selected mutations have been reviewed and endorsed by experts and AR-LBD test developers to ensure relevance and clinical significance.
In a large cfDNA-based study of more than 2,000 men with prostate cancer, AR ligand-binding-domain (AR-LBD) mutations were observed in the metastatic castration-resistant prostate cancer (mCRPC) cohort. The most frequently detected variants (L702H, H875Y, F877L, T878A, and W742C) are well-characterized alterations within the AR-LBD region. The study showed that circulating-tumor-DNA (ctDNA) analysis can reliably detect AR-LBD mutations, highlighting the importance of using accurate detection methods for these variants. (1)
*For Research Use Only. Not Intended for Clinical or Diagnostic Use
Product Description
This reference material is designed to be platform agnostic (e.g. for PCR and NGS assays).
Each vial contains defined AR-LBD variants at 1% variant allele frequency (vAF), provided as cfDNA.
Product Information
| Parameter | Specification |
| Total amount | Vials 1-3: 250 ng cfDNA, 10 ng/μL, 25 μL
Vial 4 (wildtype): 1000 ng cfDNA, 10 ng/μL, 100 μL |
| Buffer | Tris-EDTA (10 mM Tris, 1 mM EDTA), pH 8.0 |
| Storage | 2–8 °C |
| Expiration | 24 months from date of manufacture (as supplied) |
| Quality control | 1. Fragmentation size: Electrophoresis (Agilent TapeStation)
2. Allele Frequency: Digital PCR (dPCR), the metrologically recognized primary reference measurement method (2) 3. DNA Quantification: Fluorometric dsDNA measurement (Qubit) |
| Technical Background | Wild-type cfDNA corresponding to the above AR-LBD mutations |
Overview of vials and mutations:
| Vial | HGVS p. | HGVS c. | COSMIC ID (COSV) | Genomic Coordinates (GRCh38) |
| 1 | p.L702H | c.2105T>A | COSV65953052 | X:67711621-67711621 |
| p.W742C | c.2226G>C | COSV65953076 | X:67717530-67717530 | |
| p.H875Y | c.2623C>T | COSV65952830 | X:67723701-67723701 | |
| p.T878A | c.2632A>G | COSV65953150 | X:67723710-67723710 | |
| p.D891Y | c.2671G>T | COSV65959749 | X:67723749-67723749 | |
| 2 | p.V716M | c.2146G>A | COSV65953243 | X:67711662-67711662 |
| p.W742L | c.2225G>T | COSV65956522 | X:67717529-67717529 | |
| p.F877L | c.2629T>C | COSV65955698 | X:67723707-67723707 | |
| p.S889G | c.2665A>G | COSV65955708 | X:67723743-67723743 | |
| 3 | p.V716L | c.2146G>C | COSV65964440 | X:67711662-67711662 |
| p.W742C | c.2226G>T | COSV65953384 | X:67717530-67717530 | |
| p.T878S | c.2633C>G | COSV65953158 | X:67723711-67723711 | |
| p.D891H | c.2671G>C | COSV65964573 | X:67723749-67723749 | |
| 4 | Wild type | |||
How to use as workflow controls:
1. Using as Full Workflow Control:
For full workflow controls, use this reference set together with DNA-depleted plasma to create plasma samples at desired cfDNA concentrations.

2. Using at Lower Allele Frequencies
To assess your assay’s limit of detection (LOD), we recommend using the wild-type control provided with the set to perform serial dilution and generate samples with lower vAF.
Recommended Use with Laboratory-Developed Tests (LDTs)
The AR-LBD Reference Set supports:
- Test accuracy assessment
- Verification of analytical sensitivity and specificity
- Batch and reagent validation
- Error troubleshooting
Using well-characterized reference materials in LDTs supports the reliable detection of clinically relevant mutations during assay development and validation. We determine allele frequencies by dPCR, the metrologically recognized primary reference measurement method. (2) As an ISO 13485–certified manufacturer, we ensure consistent production quality.
Need specific mutations or tailored variant allele frequencies?
We offer OEM and third-party control options customized to your assay needs, including alternative mutations, defined vAFs, or kit-integrated controls. Please contact us at: sales@sens-id.com
Literature:
- Antonarakis, Emmanuel S., et al. Prevalence and spectrum of AR ligand-binding domain mutations detected in circulating-tumor DNA across disease states in men with metastatic castration-resistant prostate cancer JCO precision oncology 8 (2024): e2300330.
- Whale A. S. et al. Assessment of Digital PCR as a Primary Reference Measurement Procedure to Support Advances in Precision Medicine. Clinical Chemistry, 2018;64(9):1296–1307.
Product Description
This reference material is designed to be platform agnostic (e.g. for PCR and NGS assays).
Each vial contains defined AR-LBD variants at 1% variant allele frequency (vAF), provided as cfDNA.
Product Information
| Parameter | Specification |
| Total amount | Vials 1-3: 250 ng cfDNA, 10 ng/μL, 25 μL
Vial 4 (wildtype): 1000 ng cfDNA, 10 ng/μL, 100 μL |
| Buffer | Tris-EDTA (10 mM Tris, 1 mM EDTA), pH 8.0 |
| Storage | 2–8 °C |
| Expiration | 24 months from date of manufacture (as supplied) |
| Quality control | 1. Fragmentation size: Electrophoresis (Agilent TapeStation)
2. Allele Frequency: Digital PCR (dPCR), the metrologically recognized primary reference measurement method (2) 3. DNA Quantification: Fluorometric dsDNA measurement (Qubit) |
| Technical Background | Wild-type cfDNA corresponding to the above AR-LBD mutations |
Overview of vials and mutations:
| Vial | HGVS p. | HGVS c. | COSMIC ID (COSV) | Genomic Coordinates (GRCh38) |
| 1 | p.L702H | c.2105T>A | COSV65953052 | X:67711621-67711621 |
| p.W742C | c.2226G>C | COSV65953076 | X:67717530-67717530 | |
| p.H875Y | c.2623C>T | COSV65952830 | X:67723701-67723701 | |
| p.T878A | c.2632A>G | COSV65953150 | X:67723710-67723710 | |
| p.D891Y | c.2671G>T | COSV65959749 | X:67723749-67723749 | |
| 2 | p.V716M | c.2146G>A | COSV65953243 | X:67711662-67711662 |
| p.W742L | c.2225G>T | COSV65956522 | X:67717529-67717529 | |
| p.F877L | c.2629T>C | COSV65955698 | X:67723707-67723707 | |
| p.S889G | c.2665A>G | COSV65955708 | X:67723743-67723743 | |
| 3 | p.V716L | c.2146G>C | COSV65964440 | X:67711662-67711662 |
| p.W742C | c.2226G>T | COSV65953384 | X:67717530-67717530 | |
| p.T878S | c.2633C>G | COSV65953158 | X:67723711-67723711 | |
| p.D891H | c.2671G>C | COSV65964573 | X:67723749-67723749 | |
| 4 | Wild type | |||
How to use as workflow controls:
1. Using as Full Workflow Control:
For full workflow controls, use this reference set together with DNA-depleted plasma to create plasma samples at desired cfDNA concentrations.

2. Using at Lower Allele Frequencies
To assess your assay’s limit of detection (LOD), we recommend using the wild-type control provided with the set to perform serial dilution and generate samples with lower vAF.
Recommended Use with Laboratory-Developed Tests (LDTs)
The AR-LBD Reference Set supports:
- Test accuracy assessment
- Verification of analytical sensitivity and specificity
- Batch and reagent validation
- Error troubleshooting
Using well-characterized reference materials in LDTs supports the reliable detection of clinically relevant mutations during assay development and validation. We determine allele frequencies by dPCR, the metrologically recognized primary reference measurement method. (2) As an ISO 13485–certified manufacturer, we ensure consistent production quality.
Need specific mutations or tailored variant allele frequencies?
We offer OEM and third-party control options customized to your assay needs, including alternative mutations, defined vAFs, or kit-integrated controls. Please contact us at: sales@sens-id.com
Literature:
- Antonarakis, Emmanuel S., et al. Prevalence and spectrum of AR ligand-binding domain mutations detected in circulating-tumor DNA across disease states in men with metastatic castration-resistant prostate cancer JCO precision oncology 8 (2024): e2300330.
- Whale A. S. et al. Assessment of Digital PCR as a Primary Reference Measurement Procedure to Support Advances in Precision Medicine. Clinical Chemistry, 2018;64(9):1296–1307.